Festo AG & Co. KG

8096894
mains filter
CAMF-C6-F-C42-11A

More detailed information about this product!

Festo Data sheet

CriterionFeature
Short circuit strengthNo
Acceptable current load at 40°C42 A
Operating voltage range AC0 - 520 V
Line frequency0 - 60 Hz
Insulation voltage2650 V
Dimensions W x L x H50 mm x 295 mm x 85 mm
AuthorisationENEC
UL - Recognized (OL)
c UL - Recognized (OL)
CE mark (see declaration of conformity)in accordance with EU RoHS directive
Storage temperature-25 - 100 °C
Protection classIP20
Ambient temperature-25 - 100 °C
Product weight1400 g
Mounting typeMounting plate, bolted
Materials noteContains PWIS substances
Conforms to RoHS
Assembly positionHorizontal
Electrical connection 1, functionPower supply
Electrical connection 1, connection typeTerminal strip
Electrical connection 1, connection technologyScrewed terminal
Electrical connection 1, number of pins/wires3
Electrical connection 1, occupied pins/wires3
Electrical connection 1, conductor cross section10 - 16 mm2
Electrical connection 2, functionPower supply
Electrical connection 2, connection typeTerminal strip
Electrical connection 2, connection technologyScrewed terminal
Electrical connection 2, number of pins/wires3
Electrical connection 2, occupied pins/wires3
Electrical connection 2, conductor cross section10 - 16 mm2

© 2022 Festo AG & Co. KG