Festo AG & Co. KG

8058462
flow sensor
SFAH-0.1U-Q4S-PNLK-PNVBA-M8

More detailed information about this product!

Festo Data sheet

CriterionFeature
AuthorisationRCM Mark
c UL us - Listed (OL)
CE mark (see declaration of conformity)to EU directive for EMC
in accordance with EU RoHS directive
KC markKC-EMV
Certificate issuing departmentUL E322346
Materials noteConforms to RoHS
Measured variableMass flow rate
Volumetric flow rate
Direction of flowUnidirectional
Measuring principleThermal
Measurement methodHeat Transfer
Flow measurement range initial value0,002 l/min
Flow measurement range final value0,1 l/min
Operating pressure-0,9 - 10 bar
Operating mediumArgon
Compressed air in accordance with ISO8573-1:2010 [6:4:4]
Nitrogen
Medium temperature0 - 50 °C
Ambient temperature0 - 50 °C
Nominal temperature23 °C
Accuracy of flow rate± (2% o.m.v. + 1% FS)
Repetition accuracy zero point in ± %FS0,2 %FS
Repetition accuracy margin in ± %FS0,8 %FS
Temperature co-efficient margin in ± %FS/Ktyp. 0,15%FS/K
Pressure dependency margin in ± %FS/bar1 %FS/b.
Switch output2 x PNP or 2 x NPN switchable
Switching functionWindow comparator
Threshold value comparator
Auto difference monitoring
Switching element functionN/C or N/O contact, switchable
Max. output current100 mA
Analogue output0 - 10 V
4 - 20 mA
1 - 5 V
Characteristic curve for flow rate initial value0 l/min
Characteristic curve for flow rate final value0,1 l/min
Max. load resistance, current output500 Ohm
Min. load resistance, voltage output20 kOhm
Short circuit strengthYes
Overload withstand capabilityAvailable
ProtocolIO-Link
IO-Link, protocolDevice V 1.1
IO-Link, profileSmart sensor profile
IO-Link, function classesBinary Data Channels (BDC)
Process Data Variable (PDV)
Identification
diagnosis
Teach channel
IO-Link, communication modeCOM2 (38,4 kBaud)
IO-Link, SIO mode supportYes
IO-Link, port typeA
IO-Link, process data width IN3 Byte
IO-Link, process data content IN1 bit BDC (volume monitoring)
14 bit PDV (flow measured value)
2 bit BDC (flow monitoring)
IO-Link, Service data contents IN32-bit volume/mass measured value
IO-Link, minimum cycle time4 ms
IO-Link, data memory required< 0,5 kB
Operating voltage range DC22 - 26 V
Idle current<= 25 mA
Polarity protectedfor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connection technologyM8x1, A-coded to EN 61076-2-104
Electrical connection 1, number of pins/wires4
Mounting typewith accessories
Assembly positionAny
Pneumatic connectionFor tubing outside diameter 4 mm
Pneumatic connection, outlet directionStraight
Product weight60 g
Material housingPA-reinforced
Materials in contact with mediaAnodised wrought aluminium alloy
Epoxy resin
NBR
PA-reinforced
Silicon
Silicon nitride
High alloy steel, non-corrosive
Type of displayIlluminated LCD, multicoloured
Unit(s) that can be displayedg
g/min
l
l/h
l/min
scft
scft/h
Setting optionsIO-Link
Teach-In
Via display and buttons
Protection against manipulationIO-Link
PIN-Code
Protection classIP40
Pressure drop< 5 mbar
Safety classIII
Corrosion resistance classification CRC2 - Moderate corrosion stress
PWIS conformityVDMA24364-B2-L

© 2022 Festo AG & Co. KG