Festo AG & Co. KG
8058461
flow sensor
SFAH-0.1U-Q4S-PNLK-PNVBA-L1
More detailed information about this product!
Festo Data sheet
Criterion | Feature |
Authorisation | RCM Mark c UL us - Listed (OL) |
CE mark (see declaration of conformity) | to EU directive for EMC in accordance with EU RoHS directive |
KC mark | KC-EMV |
Certificate issuing department | UL E322346 |
Materials note | Conforms to RoHS |
Measured variable | Mass flow rate Volumetric flow rate |
Direction of flow | Unidirectional |
Measuring principle | Thermal |
Measurement method | Heat Transfer |
Flow measurement range initial value | 0,002 l/min |
Flow measurement range final value | 0,1 l/min |
Operating pressure | -0,9 - 10 bar |
Operating medium | Argon Compressed air in accordance with ISO8573-1:2010 [6:4:4] Nitrogen |
Medium temperature | 0 - 50 °C |
Ambient temperature | 0 - 50 °C |
Nominal temperature | 23 °C |
Accuracy of flow rate | ± (2% o.m.v. + 1% FS) |
Repetition accuracy zero point in ± %FS | 0,2 %FS |
Repetition accuracy margin in ± %FS | 0,8 %FS |
Temperature co-efficient margin in ± %FS/K | typ. 0,15%FS/K |
Pressure dependency margin in ± %FS/bar | 1 %FS/b. |
Switch output | 2 x PNP or 2 x NPN switchable |
Switching function | Window comparator Threshold value comparator Auto difference monitoring |
Switching element function | N/C or N/O contact, switchable |
Max. output current | 100 mA |
Analogue output | 0 - 10 V 4 - 20 mA 1 - 5 V |
Characteristic curve for flow rate initial value | 0 l/min |
Characteristic curve for flow rate final value | 0,1 l/min |
Max. load resistance, current output | 500 Ohm |
Min. load resistance, voltage output | 20 kOhm |
Short circuit strength | Yes |
Overload withstand capability | Available |
Protocol | IO-Link |
IO-Link, protocol | Device V 1.1 |
IO-Link, profile | Smart sensor profile |
IO-Link, function classes | Binary Data Channels (BDC) Process Data Variable (PDV) Identification diagnosis Teach channel |
IO-Link, communication mode | COM2 (38,4 kBaud) |
IO-Link, SIO mode support | Yes |
IO-Link, port type | A |
IO-Link, process data width IN | 3 Byte |
IO-Link, process data content IN | 1 bit BDC (volume monitoring) 14 bit PDV (flow measured value) 2 bit BDC (flow monitoring) |
IO-Link, Service data contents IN | 32-bit volume/mass measured value |
IO-Link, minimum cycle time | 4 ms |
IO-Link, data memory required | < 0,5 kB |
Operating voltage range DC | 22 - 26 V |
Idle current | <= 25 mA |
Polarity protected | for all electrical connections |
Electrical connection 1, connection type | Plug |
Electrical connection 1, connection technology | Connection pattern L1J |
Electrical connection 1, number of pins/wires | 4 |
Mounting type | with accessories |
Assembly position | Any |
Pneumatic connection | For tubing outside diameter 4 mm |
Pneumatic connection, outlet direction | Straight |
Product weight | 60 g |
Material housing | PA-reinforced |
Materials in contact with media | Anodised wrought aluminium alloy Epoxy resin NBR PA-reinforced Silicon Silicon nitride High alloy steel, non-corrosive |
Type of display | Illuminated LCD, multicoloured |
Unit(s) that can be displayed | g g/min l l/h l/min scft scft/h |
Setting options | IO-Link Teach-In Via display and buttons |
Protection against manipulation | IO-Link PIN-Code |
Protection class | IP40 |
Pressure drop | < 5 mbar |
Safety class | III |
Corrosion resistance classification CRC | 2 - Moderate corrosion stress |
PWIS conformity | VDMA24364-B2-L |
© 2022 Festo AG & Co. KG