Festo AG & Co. KG
8036873
flow sensor
SFAW-32-TG34-E-PNLK-PNVBA-M12
More detailed information about this product!
Festo Data sheet
Criterion | Feature |
Authorisation | RCM Mark c UL us - Listed (OL) |
CE mark (see declaration of conformity) | to EU directive for EMC in accordance with EU RoHS directive |
KC mark | KC-EMV |
Materials note | Conforms to RoHS |
Measured variable | Flow rate Temperature |
Direction of flow | Unidirectional P1 -> P2 |
Measurement method | Flow: vortex Temperature: PT1000 |
Flow measurement range initial value | 1,8 l/min |
Flow measurement range final value | 32 l/min |
Operating pressure | 0 - 12 bar |
Note on operating pressure | Max. 12 bar at 40°C Max. 6 bar at 100°C |
Operating medium | Fluid media Water Neutral fluids |
Note on operating and pilot medium | It must be ensured that the operating medium is compatible with the materials with which it is in contact. |
Medium temperature | 0 - 90 °C |
Ambient temperature | 0 - 50 °C |
Nominal temperature | 23 °C |
Accuracy of flow rate | ±2% FS for flow rate <= 50% FS ±3% of measured value for flow rate >= 50% FS |
Accuracy of temperature in ± °C | 2 °C |
Repetition accuracy of flow rate value | < ±0.5% FS for flow rate <= 50% FS < ±1% of measured value for flow rate >= 50% FS |
Temperature co-efficient margin in ± %FS/K | typ. ±0,05%FS/K |
Switch output | 2 x PNP or 2 x NPN switchable |
Switching function | Window comparator Threshold value comparator Freely programmable |
Switching element function | N/C or N/O contact, switchable |
Max. output current | 100 mA |
Analogue output | 0 - 10 V 4 - 20 mA 1 - 5 V |
Characteristic curve for flow rate initial value | 0 l/min |
Characteristic curve for flow rate final value | 32 l/min |
Max. load resistance, current output | 500 Ohm |
Min. load resistance, voltage output | 15 kOhm |
Short circuit strength | Yes |
Overload withstand capability | Available |
Protocol | IO-Link |
IO-Link, protocol | Device V 1.1 |
IO-Link, profile | Smart sensor profile |
IO-Link, function classes | Binary Data Channels (BDC) Process Data Variable (PDV) Identification diagnosis Teach channel |
IO-Link, communication mode | COM2 (38,4 kBaud) |
IO-Link, SIO mode support | Yes |
IO-Link, port type | A |
IO-Link, process data width OUT | 0 Byte |
IO-Link, process data width IN | 3 Byte |
IO-Link, process data content IN | 1 bit BDC (volume monitoring) 14 bit PDV (flow measured value) 2 bit BDC (flow monitoring) |
IO-Link, Service data contents IN | 32-bit measured volume value |
IO-Link, minimum cycle time | 5 ms |
IO-Link, data memory required | 0,5 kB |
Operating voltage range DC | 18 - 30 V |
Polarity protected | for all electrical connections |
Electrical connection | 5-pin A-coded M12x1 Plug straight |
Max. line length | 20 m with IO-Link operation 30 m |
Assembly position | Any |
Fluid connection | Female thread G3/4 |
Product weight | 530 g |
Material housing | PA-reinforced |
Materials in contact with media | EPDM (perox.) ETFE Stainless steel PA6T/6I reinforced |
Unit(s) that can be displayed | US gal US gal/min cft cft/min l l/h l/min m3 °C °F |
Protection class | IP65 |
Corrosion resistance classification CRC | 3 - High corrosion stress |
© 2022 Festo AG & Co. KG