Festo AG & Co. KG

8036873
flow sensor
SFAW-32-TG34-E-PNLK-PNVBA-M12

More detailed information about this product!

Festo Data sheet

CriterionFeature
AuthorisationRCM Mark
c UL us - Listed (OL)
CE mark (see declaration of conformity)to EU directive for EMC
in accordance with EU RoHS directive
KC markKC-EMV
Materials noteConforms to RoHS
Measured variableFlow rate
Temperature
Direction of flowUnidirectional
P1 -> P2
Measurement methodFlow: vortex
Temperature: PT1000
Flow measurement range initial value1,8 l/min
Flow measurement range final value32 l/min
Operating pressure0 - 12 bar
Note on operating pressureMax. 12 bar at 40°C
Max. 6 bar at 100°C
Operating mediumFluid media
Water
Neutral fluids
Note on operating and pilot mediumIt must be ensured that the operating medium is compatible with the materials with which it is in contact.
Medium temperature0 - 90 °C
Ambient temperature0 - 50 °C
Nominal temperature23 °C
Accuracy of flow rate±2% FS for flow rate <= 50% FS
±3% of measured value for flow rate >= 50% FS
Accuracy of temperature in ± °C2 °C
Repetition accuracy of flow rate value< ±0.5% FS for flow rate <= 50% FS
< ±1% of measured value for flow rate >= 50% FS
Temperature co-efficient margin in ± %FS/Ktyp. ±0,05%FS/K
Switch output2 x PNP or 2 x NPN switchable
Switching functionWindow comparator
Threshold value comparator
Freely programmable
Switching element functionN/C or N/O contact, switchable
Max. output current100 mA
Analogue output0 - 10 V
4 - 20 mA
1 - 5 V
Characteristic curve for flow rate initial value0 l/min
Characteristic curve for flow rate final value32 l/min
Max. load resistance, current output500 Ohm
Min. load resistance, voltage output15 kOhm
Short circuit strengthYes
Overload withstand capabilityAvailable
ProtocolIO-Link
IO-Link, protocolDevice V 1.1
IO-Link, profileSmart sensor profile
IO-Link, function classesBinary Data Channels (BDC)
Process Data Variable (PDV)
Identification
diagnosis
Teach channel
IO-Link, communication modeCOM2 (38,4 kBaud)
IO-Link, SIO mode supportYes
IO-Link, port typeA
IO-Link, process data width OUT0 Byte
IO-Link, process data width IN3 Byte
IO-Link, process data content IN1 bit BDC (volume monitoring)
14 bit PDV (flow measured value)
2 bit BDC (flow monitoring)
IO-Link, Service data contents IN32-bit measured volume value
IO-Link, minimum cycle time5 ms
IO-Link, data memory required0,5 kB
Operating voltage range DC18 - 30 V
Polarity protectedfor all electrical connections
Electrical connection5-pin
A-coded
M12x1
Plug straight
Max. line length20 m with IO-Link operation
30 m
Assembly positionAny
Fluid connectionFemale thread G3/4
Product weight530 g
Material housingPA-reinforced
Materials in contact with mediaEPDM (perox.)
ETFE
Stainless steel
PA6T/6I reinforced
Unit(s) that can be displayedUS gal
US gal/min
cft
cft/min
l
l/h
l/min
m3
°C
°F
Protection classIP65
Corrosion resistance classification CRC3 - High corrosion stress

© 2022 Festo AG & Co. KG