Festo AG & Co. KG
4080495
IO-Link master module
CPX-E-4IOL
More detailed information about this product!
Festo Data sheet
Criterion | Feature |
Dimensions W x L x H | 18,9 mm x 76,6 mm x 124,3 mm |
Grid dimension | 18,9 mm |
Diagnostics via LED | Error per module Status per channel |
Diagnostics via bus | Device missing/failed Wire break Module error Short circuit Parameter error Overflow/underflow Undervoltage General error |
Module parameters | Short circuit diagnostics for actuator supply Behaviour after short circuit/overload Deactivate sensor supply |
Channel parameters | Force channel x Deactivate actuator supply Device error code Channel mode Channel status Cycle time |
Protection (short circuit) | Internal electronic fuse, load per channel Internal electronic fuse, sensor for each module |
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 50 mA |
Intrinsic current consumption at nominal operating voltage load | Typically 15 mA |
Nominal operating voltage DC for electronics/sensors | 24 V |
Nominal operating voltage, DC outputs | 24 V |
Electrical isolation channel – internal bus | No |
Electrical isolation channel – channel | No |
Permissible voltage fluctuations for electronics/sensors | ± 25 % |
Permissible voltage fluctuations, load | ± 25 % |
Power supply, type of connection | Terminal strip |
Power supply, connection technology | Cage clamp terminal |
Power supply, number of pins/wires | 4 |
Power supply, conductor diameter | 0,2 - 1,5 mm2 |
Power supply, note on conductor diameter | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves |
Authorisation | RCM Mark c UL us - Listed (OL) |
KC mark | KC-EMV |
CE mark (see declaration of conformity) | to EU directive for EMC |
Certificate issuing department | UL E239998 |
Vibration resistance | Transport application test at severity level 1 in accordance with FN 942017-4 and EN 60068-2-6 |
Shock resistance | Shock test with severity level 1 in accordance with FN 942017-5 and EN 60068-2-27 |
Corrosion resistance classification CRC | 0 - No corrosion stress |
Storage temperature | -20 - 70 °C |
Relative air humidity | 95 % non-condensing |
Protection against direct and indirect contact | Protective extra-low voltage with safe disconnection (PELV) |
Protection class | IP20 |
Ambient temperature | -5 - 50 °C |
Note on ambient temperature | -5 - 50°C for horizontal installation |
Product weight | 96 g |
Protocol | IO-Link |
IO-Link, protocol | Master V 1.1 |
IO-Link, communication mode | Configurable via software SIO, COM1 (4.8 kBaud), COM2 (38.4 kBaud), COM3 (230.4 kBaud) |
IO-Link, port type | B |
IO-Link, number of ports | 4 |
IO-Link, process data width OUT | can be parameterised 8 - 32 byte |
IO-Link, process data width IN | can be parameterised 8 - 32 byte |
IO-Link, minimum cycle time | Dependent on minimum supported cycle time of the connected IO-Link® device |
IO-Link, communication | C/Q green LED |
Electrical connection for IO-Link®, connection type | 4x terminal strips |
Electrical connection for IO-Link®, connection technology | Cage clamp terminal |
Electrical connection for IO-Link®, number of pins/wires | 6 |
Electrical connection for IO-Link®, conductor cross section | 0,2 - 1,5 mm2 |
Electrical connection for IO-Link®, note on conductor cross section | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves |
Mounting type | with top-hat rail |
Materials note | Contains PWIS substances Conforms to RoHS |
Material housing | PA |
© 2022 Festo AG & Co. KG