Festo AG & Co. KG
3990296
energy efficiency module
MSE6-E2M-5000-FB36-AGD
More detailed information about this product!
Festo Data sheet
Criterion | Feature |
Size | 6 |
Series | MSE |
Assembly position | Horizontal +/- 5° |
Valve function | 2/2 open, monostable |
Operating pressure MPa | 0,35 - 1 MPa |
Operating pressure | 3,5 - 10 bar |
Authorisation | RCM Mark |
KC mark | KC-EMV |
CE mark (see declaration of conformity) | to EU directive for EMC |
Operating medium | Compressed air in accordance with ISO8573-1:2010 [7:4:4] |
Note on operating and pilot medium | Lubricated operation not possible |
Corrosion resistance classification CRC | 2 - Moderate corrosion stress |
Storage temperature | -10 - 60 °C |
Medium temperature | 0 - 50 °C |
Protection class | IP65 with plug socket |
Ambient temperature | 0 - 50 °C |
Product weight | 3300 g |
Pneumatic connection, port 1 | G1/2 |
Pneumatic connection, port 2 | G1/2 |
Material seals | NBR |
Material housing | Aluminium die cast |
Material of cover | PA-reinforced |
Material cover | PA-reinforced |
Fieldbus interface | 2x socket, M12x1, 4-pin, D-coded |
Operating voltage range, DC electronics/sensors | 18 - 30 V |
DC operating voltage, load voltage | 18 - 26,4 V |
Polarity protected | For operating voltage connections |
Unit(s) that can be displayed | kPa l l/min m3 mbar psi scf scfm |
Flow measurement range initial value | 50 l/min |
Flow measurement range final value | 5000 l/min |
Accuracy of flow rate | ± (3% o.m.v. + 0,3% FS) |
Pressure measuring range, initial value | 0 bar |
Pressure measuring range, final value | 14 bar |
Accuracy, FS | 3 %FS |
© 2022 Festo AG & Co. KG