Festo AG & Co. KG

3568167
limit switch box
SRBG-C1-N-20N-ZC-C2-C2-EX5

For electrical feedback and position monitoring of process valves actuated with pneumatic quarter turn actuators, inductive measuring principle.

More detailed information about this product!

Festo Data sheet

CriterionFeature
DesignAngular
Based on the standardEN 60947-5-6
VDI/VDE 3845
AuthorisationRCM Mark
c UL us (OL)
CE mark (see declaration of conformity)to EU directive for EMC
to EU directive explosion protection (ATEX)
in accordance with EU RoHS directive
ATEX category GasII 1G
Explosion ignition protection type GasEx ia IIC T6...T1 Ga
Explosion protection certification outside the EUEPL Da (CN)
EPL Ga (CN)
EPL Ga (IEC-EX)
Explosion-proof ambient temperatureSee ATEX certificate
See IECEx certificate
effective inductivity100 µH
effective capacity100 nF
Max. input parameters for intrinsically safe circuitSee IECEx certificate
See ATEX certificate
Certificate issuing departmentGYJ20.1662X
IECEx TUN 18.0003X
TÜV 16 ATEX 174269 X
Materials noteConforms to RoHS
Safety Integrity Level (SIL)SIL 2
Measuring principleInductive
Ambient temperature-25 - 100 °C
Switch outputNAMUR
Switching element functionNormally closed contact
Max. switching frequency3000 Hz
Max. output current DC3 mA
Short circuit strengthYes
Operating voltage range DC8,2 V
Polarity protectedfor all electrical connections
Electrical connection 1, connection typeTerminal strip
Electrical connection 1, cable outletStraight
Electrical connection 1, designRound
Electrical connection 1, connection technologyCage clamp terminal
Electrical connection 1, number of pins/wires10
Connectable nominal conductor cross section0,2 - 2,5 mm2
Cable gland connectionM12x1,5
M20x1,5
Mounting typeThreaded
Assembly positionAny
Product weight170 g
Material housingPBT
Material screwsHigh alloy steel, non-corrosive
Operating status displayYellow LED
Status displayYellow LED = valve switching status
Storage temperature-40 - 100 °C
Protection classIP67
Shock resistanceShock test with severity level 2 in accordance with FN 942017-5 and EN 60068-2-27
Vibration resistanceTransport application test at severity level 2 in accordance with FN 942017-4 and EN 60068-2-6
PWIS conformityVDMA24364 zone III
Degree of contamination3

© 2022 Festo AG & Co. KG