Criterion | Feature |
Stroke | 20 mm |
Piston diameter | 14 mm |
Max. replacement accuracy | 0,3 mm |
Max. stem backlash Sx | 0,05 mm |
Max. stem backlash Sz | 0,03 mm |
Max. angular gripper jaw backlash ax | 0,12 deg |
Max. angular gripper jaw backlash ay | 0,2 deg |
Max. angular gripper jaw backlash az | 0,175 deg |
Mounting of external fingers | Through-hole |
Cushioning | No cushioning |
Assembly position | Any |
Mode of operation | double-acting |
Design structure | Piston rod Non-rotating |
Position detection | For proximity sensor |
Protection against torque/guide | Square guide |
Operating pressure | 3 - 8 bar |
Advancing time | 50 ms |
Return-stroke time | 138 ms |
Repetition accuracy | 0,15 mm |
Operating medium | Compressed air in accordance with ISO8573-1:2010 [7:4:4] |
Note on operating and pilot medium | Lubricated operation possible (subsequently required for further operation) |
Corrosion resistance classification CRC | 2 - Moderate corrosion stress |
Ambient temperature | 5 - 60 °C |
Max. force on finger Fz static | 100 N |
Max. torque at gripper finger Mr static | 5 Nm |
Max. torque at finger Mx static | 5 Nm |
Max. torque at finger My static | 5 Nm |
Theoretical force at 0.6 MPa (6 bar, 87 psi), retracting | 75 N |
Theoretical force at 0.6 MPa (6 bar, 87 psi), advance | 90 N |
Max. mass per external gripper finger | 150 g |
Product weight | 183 g |
alternative connections | M5 |
Mounting type | Internal thread and centring sleeve With through-hole and centring sleeve Optional |
Pneumatic connection | M5 |
Materials note | Free of copper and PTFE Conforms to RoHS |