Festo AG & Co. KG
1622904
motor controller
CMMP-AS-C10-11A-P3-M0
More detailed information about this product!
Festo Data sheet
Criterion | Feature |
Mounting type | On sub-base Tightened |
Product weight | 3800 g |
Display | Seven-segment display |
Authorisation | RCM Mark c UL us - Listed (OL) |
CE mark (see declaration of conformity) | to EU directive for EMC to EU directive for machinery to EU directive low-voltage devices in accordance with EU RoHS directive |
Certificate issuing department | 01/205/5162.02/19 TÜV Rheinland |
Storage temperature | -25 - 70 °C |
Ambient temperature | 0 - 40 °C |
Relative air humidity | 0 - 90 % |
Protection class | IP10 IP20 |
Degree of contamination | 2 |
Materials note | Conforms to RoHS |
PWIS conformity | VDMA24364 zone III |
Nominal operating voltage, phases | Three-phase |
Nominal operating voltage, AC | 400 V |
Permissible voltage fluctuation | +/- 10 % |
Line frequency | 50 - 60 Hz |
Nominal current | 11 A |
Mains filter | Integrated |
Max. intermediate circuit voltage, DC | 560 V |
Braking resistance | 68 Ohm |
Braking resistance pulse power | 8,5 kVA |
Nominal DC voltage, logic power supply | 24 V |
Permissible range, logic voltage | ± 20 % |
Current consumption, logic power supply without clamping brake | 1 A |
Output voltage range AC | 3x 0 - 360 V |
Nominal output current | 10 A |
Effective nominal current per phase | 10 A |
Effective peak current per phase | 20 A |
Max. peak current duration | 5 s |
Nominal controller power | 6000 VA |
Peak power | 12000 VA |
Output frequency | 0 - 1000 Hz |
Parameters configuring interface | Parameters configuration and commissioning USB Ethernet |
Fieldbus coupling | CANopen Modbus/TCP |
Communications profile | DS301/DSP402 |
Process interface | I/O coupling For 256 position sets |
Max. fieldbus transmission speed | 1 Mbit/s |
Bus connection | Plug 9-pin Sub-D |
Encoder interface output, characteristics | Resolution 16384 ppr |
Encoder interface output, function | Actual value feedback via encoder signals in speed control mode Setpoint specification for downstream slave drive unit |
Encoder interface input, characteristics | 3-phase encoding signals EnDat HIPERFACE RS422 SINCOS |
Encoder interface input, function | Encoder signal, speed setpoint in RPM In synchronous operation as specified speed in RPM for the slave drive unit |
Number of digital logic inputs | 10 |
Logic input characteristics | Electrically isolated Freely configurable |
Logic input working range | 8 - 30 V |
Number of 24 V DC digital logic outputs | 5 |
Digital logic output characteristics | Electrically isolated Freely configurable to a given extent |
Max. current, digital logic outputs | 100 mA |
Number of analogue setpoint inputs | 2 |
Setpoint input characteristics | Differential inputs Can be configured for speed in RPM Can be configured for current |
Setpoint input working range | ± 10 V |
Setpoint input impedance | 20 kOhm |
Number of analogue monitor outputs | 2 |
Monitor output working range | ± 10 V |
Monitor output resolution | 9 bit |
Monitor output characteristics | Short-circuit proof |
Safety function | Safe torque off (STO) Safe stop 1 (SS1) |
Safety Integrity Level (SIL) | Safe torque off (STO)/SIL 3/SILCL 3 |
Performance level (PL) | Safe Torque off (STO)/Category 4, Performance Level e |
Diagnostic coverage | 97 % |
SFF Safe Failure Fraction | 99,17 % |
Hardware fault tolerance | 1 |
Proof test interval | 20 a |
© 2022 Festo AG & Co. KG