Festo AG & Co. KG

1622901
motor controller
CMMP-AS-C2-3A-M0

More detailed information about this product!

Festo Data sheet

CriterionFeature
Mounting typeOn sub-base
Tightened
Product weight2100 g
DisplaySeven-segment display
AuthorisationRCM Mark
c UL us - Listed (OL)
CE mark (see declaration of conformity)to EU directive for EMC
to EU directive for machinery
to EU directive low-voltage devices
in accordance with EU RoHS directive
Certificate issuing department01/205/5162.02/19
TÜV Rheinland
Storage temperature-25 - 70 °C
Ambient temperature0 - 40 °C
Relative air humidity0 - 90 %
Protection classIP10
IP20
Degree of contamination2
Materials noteConforms to RoHS
PWIS conformityVDMA24364 zone III
Nominal operating voltage, phasesSingle-phase
Nominal operating voltage, AC230 V
Permissible voltage fluctuation+/- 10 %
Line frequency50 - 60 Hz
Nominal current2 - 3 A
Active PFCYes
Mains filterIntegrated
Max. intermediate circuit voltage, DC320 V
Braking resistance60 Ohm
Braking resistance pulse power2,8 kVA
Nominal DC voltage, logic power supply24 V
Permissible range, logic voltage± 20 %
Current consumption, logic power supply without clamping brake0,55 A
Output voltage range AC3x 0 - 270 V
Nominal output current2,5 A
Effective nominal current per phase2,5 A
Effective peak current per phase5 A
Max. peak current duration5 s
Nominal controller power500 VA
Peak power1000 VA
Output frequency0 - 1000 Hz
Parameters configuring interfaceParameters configuration and commissioning
USB
Ethernet
Fieldbus couplingCANopen
Modbus/TCP
Communications profileDS301/DSP402
Process interfaceI/O coupling
For 256 position sets
Max. fieldbus transmission speed1 Mbit/s
Bus connection9-pin
Sub-D
Plug socket
Encoder interface output, characteristicsResolution 16384 ppr
Encoder interface output, functionActual value feedback via encoder signals in speed control mode
Setpoint specification for downstream slave drive unit
Encoder interface input, characteristics3-phase encoding signals
EnDat
HIPERFACE
RS422
SINCOS
Encoder interface input, functionEncoder signal, speed setpoint in RPM
In synchronous operation as specified speed in RPM for the slave drive unit
Number of digital logic inputs10
Logic input characteristicsElectrically isolated
Freely configurable
Logic input working range8 - 30 V
Number of 24 V DC digital logic outputs5
Digital logic output characteristicsElectrically isolated
Freely configurable to a given extent
Max. current, digital logic outputs100 mA
Number of analogue setpoint inputs2
Setpoint input characteristicsDifferential inputs
Can be configured for speed in RPM
Can be configured for current
Setpoint input working range± 10 V
Setpoint input impedance20 kOhm
Number of analogue monitor outputs2
Monitor output working range± 10 V
Monitor output resolution9 bit
Monitor output characteristicsShort-circuit proof
Safety functionSafe torque off (STO)
Safe stop 1 (SS1)
Safety Integrity Level (SIL)Safe torque off (STO)/SIL 3/SILCL 3
Performance level (PL)Safe Torque off (STO)/Category 4, Performance Level e
Diagnostic coverage97 %
SFF Safe Failure Fraction99,17 %
Hardware fault tolerance1
Proof test interval20 a

© 2022 Festo AG & Co. KG