Festo AG & Co. KG

1501331
safety module
CAMC-G-S3

One plug-in module CAMC-DS-M1, CAMC-G-S1 or CAMC-G-S3 is required in order to operate the motor controller CMMP-AS-…-M3.

More detailed information about this product!

Festo Data sheet

CriterionFeature
Nominal DC voltage, logic power supply24 V
Nominal operating voltage DC24 V
Nominal current, logic supply0,15 A
Permissible range, logic voltage± 20 %
Current consumption, logic power supply without clamping brake0,2 A
Short circuit strengthYes, exception: contact C1/C2
Acceptable current load at 40°C0,2 A
Protection (short circuit)No
Design of the digital outputPotential-free signal contact
3 safe, 2-channel semiconductor outputs
Number of digital logic inputs10
Digital outputs, switching logicSemiconductor outputs: parameterisable PNP (positive switching) 2-channel equivalent/antivalent
Dimensions W x L x H112,2 mm x 99,1 mm x 28,7 mm
Product-specific LED displayError (red)
Normal operation (green)
Safe state (yellow)
Safety functionSafe brake control (SBC)
Safe speed range (SSR)
Safe speed monitor (SSM)
Safe torque off (STO)
Safely-limited speed (SLS)
Safe operating stop (SOS)
Safe stop 1 (SS1)
Safe stop 2 (SS2)
Probability of Failure per Hour in [1/h].9,50000000E-09
Proof test interval20 a
Hardware fault tolerance1
SFF Safe Failure Fraction99,5 %
Certified for safety function to ISO 13849 and IEC 61508 (SIL)Product can be used in SRP/CS up to SIL 3 (high demand)
Safety Integrity Level (SIL)Safe brake control (SBC)/SIL 3
Safely limited speed (SLS)/SIL 3
Safe operating stop (SOS)/SIL 3
Safe stop 1 (SS1)/SIL 3
Safe stop 2 (SS2)/SIL 3
Safe Speed Monitor (SSM)/SIL 3
Safe Speed Range (SSR)/SIL 3
Safe torque off (STO)/SIL 3
Performance level (PL)Safe brake control (SBC)/category 4, Performance Level e
Safely limited speed (SLS)/category 3, Performance Level e
Safe operating stop (SOS)/category 3, Performance Level e
Safe stop 1 (SS1)/category 3, Performance Level e
Safe stop 2 (SS2)/category 3, Performance Level e
Safe speed monitor (SSM)/category 3, Performance Level e
Safe speed range (SSR)/category 3, Performance Level e
Safe Torque off (STO)/Category 4, Performance Level e
Diagnostic coverage97,5 %
Certified for safety functions to ISO 13849 (PL)Product can be used in SRP/CS up to category 4, PL e
AuthorisationTÜV
CE mark (see declaration of conformity)to EU directive for EMC
to EU directive for machinery
Certificate issuing department01/205/5165.02/19
TÜV Rheinland
PWIS conformityVDMA24364 zone III
Storage temperature-25 - 55 °C
Relative air humidity5 - 90 %
non-condensing
Protection classIP20
in assembled condition
Ambient temperature0 - 40 °C
Product weight220 g
Mounting typePlug-in module for CMMP-AS...-M3
Materials noteConforms to RoHS
Assembly positionAny
Wire endsWire end ferrule
Terminal cross-section0,25 - 0,5 mm2
Electrical connectionScrewed terminal
Plug straight
DisplayLED green/yellow/red
Control elementsDIP switches
Specification, logic inputIEC 61131-2, type 3
Logic input characteristics4 safe, 2-channel inputs Equivalent/antivalent switching Test pulses configurable Function configurable
6 safe, 1-channel inputs Test pulses configurable
Logic input working range13 - 28,8 V
Max. nominal input current0,015 A
Debouncing time, inputs0,3 ms
Current-carrying capacity per output50 mA
Max. current, digital logic outputs50 mA
Fuse protection, outputShort-circuit and cross-circuit monitoring
Minimum cycle time2 ms
Parameters configuringVia SafetyTool

© 2022 Festo AG & Co. KG