Festo AG & Co. KG

553553
fork light barrier
SOOF-M-FL-SM-C30-P

Stable metal housing.

More detailed information about this product!

Festo Data sheet

CriterionFeature
AuthorisationRCM Mark
c UL us - Listed (OL)
CE mark (see declaration of conformity)to EU directive for EMC
Materials noteContains PWIS substances
Conforms to RoHS
Measured variablePosition
Measuring principleOptoelectronic
Measurement methodFork light barrier
Type of lightRed
Minimal object diameter0,3 mm
Note on min. object diameter0.3 mm with standard mode
0.2 mm with high resolution mode
1.0 mm with power mode
0.3 mm with speed mode
Ambient temperature-25 - 60 °C
Repetition accuracy0,02 mm
Switch outputPush-pull
NPN
PNP
Switching element functionSwitchable
Hysteresis<= 0,1 mm
Max. switching frequency5000 Hz
Note on switching frequency5000 Hz with standard mode
1500 Hz with high resolution mode
250 Hz with power mode
8000 Hz with speed mode
Max. output current100 mA
Timer functionVia IO-Link®
Short circuit strengthPulsing
ProtocolIO-Link
IO-Link, protocolDevice V 1.1
IO-Link, profileSmart sensor profile
IO-Link, function classesBinary Data Channels (BDC)
Process Data Variable (PDV)
Identification
diagnosis
Teach channel
IO-Link, communication modeCOM2 (38,4 kBaud)
IO-Link, SIO mode supportYes
IO-Link, port typeA
IO-Link, process data width OUT0 Byte
IO-Link, process data width IN2 Byte
IO-Link, process data content IN1 bit BDC (Switching Signal)
1 bit BDC (Stability)
12 bit PDV (Signal Level)
IO-Link, Service data contents IN32 bit Switching Counter
16 bit Temperature
8 bit Teach-In Quality
16 bit Minimum Signal Level
16 bit Maximum Signal Level
IO-Link, minimum cycle time2,3 ms
IO-Link, data memory required73 Byte
Operating voltage range DC10 - 30 V
Residual ripple± 5 %
Idle current30 mA
Polarity protectedfor all electrical connections
Electrical connection3-pin
M8x1
Plug
SizeClevis 30x35 mm
Fork gap30 mm
Product weight68 g
Material housingDie-cast zinc, coated
Operating status displayYellow LED
Setting optionsIO-Link
Potentiometer
Protection classIP67
Insulation voltage500 V
Surge strength0,8 kV
Corrosion resistance classification CRC0 - No corrosion stress
Degree of contamination3