Festo AG & Co. KG

549292
sensor interface
CASM-S-D2-R3

More detailed information about this product!

Festo Data sheet

CriterionFeature
Diagnosis functionDisplay via LED
Assembly positionAny
Power supply requirementProtective extra-low voltage with safe disconnection (PELV)
Nominal operating voltage DC24 V
Power failure buffering10 ms
Residual ripple4 Vss
Current consumption at nominal operating voltage40 - 50 mA
Permissible voltage fluctuation+/- 25 %
AuthorisationRCM Mark
KC markKC-EMV
CE mark (see declaration of conformity)to EU directive for EMC
in accordance with EU RoHS directive
Continuous shock resistance per DIN/IEC 68, parts 2 - 82Tested in accordance with severity level 2
Corrosion resistance classification CRC1 - Low corrosion stress
Storage temperature-20 - 70 °C
Relative air humidity95 %
non-condensing
Protection classIP67
Connected plug connector
Vibration resistance per DIN/IEC 68, parts 2 - 6Tested in accordance with severity level 2
Ambient temperature0 - 55 °C
Product weight128 g
Electrical connection, measuring systemM12
Plug socket
5-pin
Control interface electrical connectionPlug
M9
5-pin
Control interfaceDigital
CAN bus with Festo protocol
Without terminating resistor
Mounting typewith through hole
Material housingPBT-reinforced

© 2022 Festo AG & Co. KG